Paper Infomation
Cold Half Pressure Type LPG Ship Re-liquefied System Operation Mode Research
Full Text(PDF, 296KB)
Author: Tong Zhengming, Bao Jiayong, Zhou Bo, Zhu Jiadong, He Juncheng
Abstract: With the growing use of the liquefied petroleum gas (LPG), fast development of liquefied gas transportation at sea, the demand for LPG ship at home and abroad are greatly increased. Lots of cold half pressure type LPG have been manufactured by our country. Re-liquefied system is avery important equipment on this kind of ship. In order to provide references for the design of the liquefaction system. Based on the types of working medium, choosing matched refrigerating cycle. By derivation, the theoretical formula is calculated two-stage compression and single-stage compression system. Through thermodynamic calculation of thermodynamic parameters, through analyzing and comparing different liquid working medium under different design pressure and the capacity of refrigeration coefficient, provide references for the design of the re-liquefaction system.
Keywords: LPG Ship, Cold Half Pressure, Re-Liquefied System, Two-Stage Compression
References:
[1] Pinyou Li. “Low Temperature Liquefied Gas Ship Reliquefier Overview”Ship & Boat, 1996, 05: 35-37+54+2.
[2] Pinyou Li, Anzhong Gu “Low Temperature Liquefied Gas Ship Refrigeration Unit-Reliquefier” Refrigeration, 1996, 03: 65-67.
[3] Cheyou Zhang. Refrigeration and Cryogenic Technology. Beijing: China Machine Press, 1981
[4] Xiaomin Wu,R L Webb, Weicheng Wang. “The influence of the regenerator of the refrigeration system”. Journal of University of Shanghai for Science and Technology, 2001, 03: 247-251.
[5] Jinkun Zhou. “Study on subcooling and energy saving in two stage compression cycle”. Journal of Wuxi Institute of Commerce, 2005, 02: 9-10.
[6] Xiande Zhen. The refrigeration principle and device. Beijing: China Machine Press, 2008.3
[7] Taifeng Wang, Xinping Ouyang, Na Xue. “Experimental research on refrigeration performance of thermoelectric-refrigerating unit”. Journal of University of Shanghai for Science and Technology,2007,04:341-344
[8] Zhigang Liu. Working medium thermal physical property calculationprogram of preparation and application. Beijing: Science Press, 1992.
[9] Peng Guan, Kai Zhao,Baiqiang Zhai,et al.“Analysis and calculation of thermodynamic cycle about two-stage compression refrigeration system”. Refrigeration and Air-Conditioning,2007,7(2):43-47
[10] Gang Zhu, Xuesheng Lu, Rongshun Wang, et al. “Study on Reliquefaction Plant in LPG Carrier”. Refrigeration,1999,04:310-314