Paper Infomation
Performance Analysis on the Internal Force of Steel Frame Column Base
Full Text(PDF, 625KB)
Author: Kewei Ding, Yahong Xu
Abstract: Using the finite element software ANSYS to a single span two layers of steel frame model under outside load, the internal force of semi-rigid column footing of performance analysis, and with the same conditions of rigid frame column base bending moment, shear force, axial force and displacement are analyzed in this paper, which comprehensively reflects the semi-rigid nodes can improve the stress of the structure of column foot to certain extent, and also can improve the ability of energy dissipation frame structure.
Keywords: Column Base; Semi-rigid Connection; Internal Force
References:
[1] Ding Haoming, Shen Zuyan. A practical calculating model for semi-rigid connections[J]. Industrial Construction. 1992(11): 29-32.(In Chinese)
[2] Shen Zuyan. A practical calculating model for semi-rigid connections[J]. Industrial Construction, 1990, 20(6): 29-32.(In Chinese)
[3] Jin Kanhui, Duan Shujin. The Mechanical Properties Analysis and Application of A New Column Base Connection. [D]. Shijiazhuang Tiedao University.2012. 22-50(In Chinese)
[4] Wang Xintang Explicit stiffness of spatial beams with arbitrary connections[J]. Space Structure.2003. 9(3):33-37. (In Chinese)
[5] Li Qingfu. Semi-rigid connection steel frame deformation research[J]. Lanzhou. Lanzhou University of Technology. 2004. 14-22(In Chinese)
[6] Dong Shilin, Zhao Yang, Zhou Dai. Space steel structure in our country in the development of new technology and new structure[J]. China Civil Engineering Journal, 1998. 31(6):3-14. (In Chinese)
[7] Xu Manhua. The Research on Mechanical Behavior of Steel Frames with Semi-rigid Connections[J]. Changsha, Changsha University of Science and Technology,2005 .11-23(In Chinese)
[8] Wang Lai, Wang Qi, Zhao Yanhong. Frame structure finite element analysis of the performance of semi-rigid connection[J]. Journal of Shandong University of Science and Technology, 2008, 27(1): 39-43. (In Chinese)
[9] Li Guoqiang, Shen Zuyan. Semi-rigid connection steel frame elastic-plastic seismic response analysis[J]. Journal of Tongji University, 1992. 20(2):123-128. (In Chinese)
[10] Li Guoqiang, Shen Zuyan. Steel frame elastic-plastic nonlinear analysis model of the static and dynamic response[J]. Journal of Building Structures, 1990. 11(2):51-59. (In Chinese)
[11] LIGHT base E, ANDREW PLM. Elastic Analysis of Frame works with Elastic Connections[J]. Journal of the Structure Division, ASCE, 1974, 100(6): 1297-1309
[12] JONES SW, PATRICK AP, NETHERCOT DA. Column with Semi-rigid Joints [J]. Journal of the Structural Division, ASCE, 1982, 108(2): 361-372
[13] HADIANFARD MA, RAZANI R. Effect of Semi-rigid Behavior of Connections in the Reliability of Steel Frames[J].Structure Safety, 2003, 25(2): 123-138
[14] BJORHOVDE R, COLSON A, BROZZETTI J. Classification System for Beam-to-beam Connection[J], Journal of Structural Engineering, 1990, 116(11): 3059-3076
[15] LI GQ, JOHN M. Approximate Estimation of the Maximum Load of Semi-rigid Steel Frames[J]. Journal Constructional Steel Research, 2000, 54(2): 213-225