Paper Infomation
Performance Simulation of 300MW Turbine Generator by Ansoft Maxwell
Full Text(PDF, 387KB)
Author: Cai Chen, Shuquan zhang, Huijuan Liu
Abstract: The finite element model of a 300MW turbine generator is established by means of the finite element analysis software¬¬¬¬-Maxwell in this paper. Through the simulation analysis, the operating characteristics and various electromagnetic parameters including no-load characteristic, short-circuit characteristic, air-gap flux density, stator induced voltage, electromagnetic torque and reactance parameters of the generator as well as the core-loss are obtained. Compared with the design values, the simulation model established is verified by the simulation results.
Keywords: 300MW Turbine Generator; Electromagnetic Performance; Finite Element Analysis (FEA)
References:
[1] Wang Yi-Xuan;Wang Ying;Liu Xin;Qiu Hai-Fei.“Electromagnetic design and dynamic analysis of large turbo-generator”, Journal of Enerhy and Power Engineering, pp.19-28, Dec. 2009.
[2] Wladyslaw Paszek, Jan Staszak. “Electromagnetic Parameters of a Turbine generator Determined by the Finite Element Calculation”, Electromagnetic Fields in Electrical Engineering, pp. 171-176, 1988.
[3] Michael G. Pantelyat, Oszkár Bíró, Andrej Stermecki, “Transient electromagnetic field, losses and forces in a synchronous turbine generator rotor”, The international journal for computation and mathematics in electrical and electronic engineering, Vol. 32,no. 3, pp.794-808, 2013.
[4] M. A. Arjona L. “Discussion of Parameter calculation of a turbinegenerator during an open-circuit transient excitation”, IEEE Transactions on Energy Conversion .vol.19, no.1, p.46-52, Mar.2004.
[5] Yang Zhao,Bo Yan, Changlin Chen, Jianan Deng, Qingwu Zhou, “Parametric Study on Dynamic Characteristics of Turbine generator Stator End Winding”, IEEE Transactions on Energy Conversion, Vol. 29, no. 1, pp. 129-137, Mar. 2014.
[6] Shima K, Ide K, Takahashi M, “Finite-element calculation of leakage inductances of a saturated salient-pole synchronous machine with damper circuits”, IEEE Transactions on Energy Conversion, vol. 17, no. 4, pp. 463-470, Aug.2002.
[7] D. Ban, D. Zarko, Z. Maljkovic. “The application of finite element method for more accurate calculation and analysis of turbinegenerator parameters”, Electric Machines and Power Systems, Vol. 26, no. 10, pp.1081-1093, Dec. 1998.
[8] Jinyao Hu, “Electromagnetic Parameter Calculation and Transient Performance Analysis for Large Turbo-generator”, Harbin University of Science and Technology, pp.16-47, Mar.2012.
[9] R. Mizokami, M. Kimura and M. Muraoka, “Electromagnetic field analysis for the new series of air-cooled, two-pole turbine-generator”, Fuji Electric journal, Vol. 72, pp. 271-274. 1999.
[10] Huijuan Liu, Yu Fan. Electrical Machinery. China Machine Press, Beijing, pp.200-230, Apr.2014.